Individual Production
MIDPOINT measurement contributes to more personal accurate vision and thickness compensation

Bow Frame (Horizontal Slope) Angle Measurement
Place the top of the frame opposite the horizontal axis as shown in the diagram.
Hold firmly the center of the bridge on the M point.
Lay the left side of the frame on the horizontal axis.
Measure and document the angle of the right side frame placement.